UCD-50 Industrial Ultrasonic Flaw Detector

New universal ultrasonic flaw detector with colour TFT a matrix 640х480 and magnificent speed is optimal a choice for the expert testing. Powerful, easy and portable (weight only 2 kg with the batteries), in the ergonomic shock-resistant case from ABS a plastic, the device establishes the new standard for modern digital devices of the manual testing. Flaw detector UCD-50 allows measuring a thickness of products with the big accuracy, to deduce a signal in a form A - and B-scan and possesses all functions on full documenting of the testing, with software UdReport.  
The mode bending around a signal maximum is realized on the basis of special algorithm of device UD2V-P46. 

Certificated of Gosstandard of Russia RU.C.27.003.A №27966, is registred in the National register of means of measurements under №34900-07 alsoadmitted to application in the Russian Federation.  

  • Display: Colour TFT 135 x 100 mm (640 х 480 pixels)
  • Amplifier: broadband 0.4 - 15 МHz
  • TGC/DAC functions
  • Work with curve amplitude-interval: measurement in dB echelop signal relative curve and operation LED
  • Pulse repetition frequency: to 800 Hz
  • Monitor gate: 2 independent monitor gates with individual logic
  • А-, В- scan
  • Interface RS232, USB
  • Mains power: LiOn batterie or via external plug-in power unit.
  • Maximal 8 hours from batteries

 Basic Delivery Set

  • UCD-50 main unit
  • Batteries
  • Power supply 220 V
  • Cable SR50-Lemo 2 pieces.
  • Four transducers
  • Cable for connection PC
  • Software support for connection PC
  • Documentations
  • Transport bag

 Additional implements

  • Protective bag
  • Ultrasonic transducers for different application
  • Standard samples

 Technical Characteristics

  • Calibration Range: min.: 0 - 4 mks, max.: 0 - 1000 mks, adjustable with step 1 mks
  • Pulse shift: up to -0,5 mks to 996 mks, with step up to 0,02 mks
  • The maximum length of a testinglable Material: to 3000 mm (echo-mode)
  • Sound velocity range: 1000 - 9999 m/s
  • Proble delay: 0 - 100 mks, with step 0,01 mks
  • Damping: 25 оhms / 50 оhms/ 1000 ohms
  • Receiver: 50 ohms / 600 ohms
  • Probe pulse: radio-frequency pulse, amplitude 50 or 200V
  • Pulse repetition frequency: to 800Hz (depending on parameters setting)/ 40 Hz
  • Frequency range: broadband 0.4-15 МHz (-6 dB)
  • Controllable gain: 110 dB, with step 0.5, 1, 2 or 6 dB
  • Additional button +dB: programming 0-40dB, with step 0,5dB
  • TGC/DAC:90 dB, 12 dB/mks, curve recording with maximum of 10 reference echoes
  • Rectification: RF(in all ranges), full-wave, positive and negative half wave, B-scan
  • Reject: 0 - 90% screen height
  • Monitor gate: 2 independent monitor gates with individual logic, sound indication 
  • Alarm: luminous and sonorous 
  • Sound path measurement: up to 0 to first signal in zone or between signals in zones
  • Display of amplitude: as a percentage of the screen height, in dB to reference test echo, in dB referens to DAC curve
  • Display: Colour, TFT 640 х 480 pixels, 130 х 100 mm
  • А-signal: 480 x 300 pixels in a standard mode, 640х480 in full-screen mode
  • Memory: 100 datasets with А-signal, 500 reports of the testing (signal, measured results, parameters transducers, date, time and name report)
  • Interface: RS232 / USB
  • Dimensions transducers: 2 Lemo0
  • Batteries: LiOn 8 А/hr
  • Operating time: 8 hours from batteries
  • Mains power: 220 V AC
  • Operating temperature: up to -20 C to +50 C
  • Dimensions (H x W x D): 200 mm x 225 mm x 80 mm
  • Weight: 2 kg with batteries