- ANATHERM Heat Treatment Units
- Ultrasonic Test Equipments
- Ultrasonic Flaw Detectors
- A1211 Tiny Ultrasonic Flaw Detector
- A1212 MASTER Ultrasonic Flaw Detector
- A1214 EXPERT Ultrasonic Flaw Detector
- A1550 IntroVisor Ultrasonic Tomograph
- KUT-800 Ultrasonic Flaw Detector
- KUT-700 Ultrasonic Flaw Detector
- KUT-650 Ultrasonic Flaw Detector
- KUT-600 Ultrasonic Flaw Detector
- KUT-500 Ultrasonic Flaw Detector
- UCD-60 Industrial Ultrasonic Flaw Detector
- UCD-50 Industrial Ultrasonic Flaw Detector
- A1220 ANKER Low-frequency flaw detector
- Ultrasonic Scanners
- Thickness Gauges
- Coating Thickness Gauges
- Ultrasonic Flaw Detectors
- Radyographic Test Equipments
- Eddy Current Testers
- Hardness Testers
- Portable Hardness Testers
- Rockwell Hardness Testers
- THR-150 Manual Rockwell Hardness Tester
- THR-150D Digital Rockwell Hardness Tester
- THR-150D(H) Digital Rockwell Tester
- THR-150M Electric Rockwell Hardness Tester
- THR-150M(H) Electric Rockwell Tester
- THR-150-P Plastic Rockwell Hardness Tester
- THR-45 150D Digital HR, Superficial Rockwell Tester
- THR-45D Digital Superficial Rockwell Hardness Tester
- THR-45M Electric Superficial Rockwell Hardness Tester
- THR-150DC Nosed Digital Rockwell Hardness Tester
- THRS-150D-Z Full Automatic Rockwell Hardness Tester
- THR-150D-Z Automatic Rockwell Hardness Tester
- THRS-150D-ZXY Fully Automatic Rockwell Hardness Tester
- Vickers Hardness Testers
- THV-5 Vickers Hardness Tester
- THV-5D Vickers Hardness Tester
- THV-5M Automatic Turret Vickers Hardness Tester
- THV-5MD Automatic Turret Vickers Tester
- THV-10 Vickers Hardness Tester
- THV-10D Dijital Vickers Sertlik Testi
- THV-10M Automatic Turret Vickers Tester
- THV-10MD Automatic Turret VickersTester
- THV-30 Vickers Hardness Tester
- THV-30D Digital Vickers Hardness Tester
- THV-30M Automatic Turret Vickers Hardness Tester
- THV-30MD Digital Automatic Turret Vickers Hardness Tester
- THV-50 Vickers Hardness Tester
- THV-50D Digital Vickers Hardness Tester
- THV-50M Automatic Turret Vickers Hardness Tester
- THV-50MD Digital Automatic Turret Vickers Hardness Tester
- THVS-M Vickers Hardness Measuring System
- THVS-1M-AXYZF Fully Automatic Micro Vickers Hardness Test System
- Micro Vickers Hardness Testers
- Brinell Hardness Testers
- Universal Hardness Testers
- Accessoires
- Concrete Test Equipments
- Measuring Test Equipments
- Coating and Paint Test Equipments
- Railway and Rail Test Equipments
- ANATHERM CATALOGUES
- ANATHERM Heat Treatment Units
The A-Scan feature allows ruling out false results considerably increasing the inspection reliability, to conduct express-searches of foreign inclusions and laminations and to get true results of measuring through polymeric, varnish and paint and other types of insulated coating. The thickness gauge A1210 has a whole range of features to provide comfort and effective work:
The large TFT display ensures the full visual control of the inspection process with the help of color indications. The magnetic holder helps to fix the thickness gauge safely to metal surfaces for comfort work at hard-to reach places and at heights. Advantages 1) Colour high-contrast TFT display 2) A-Scan mode with an option to save images to the memory 3) Metal thickness measuring through insulated coating at the A-Scan mode 4) Nonvolatile memory for 50 000 measurements including 4 000 A-Scan images 5) USB connection to PC 6) Automatic logging of the maximum and minimum values at multiple measurements or while scanning the object 7) Automatic measuring of the ultrasonic wave velocity at a sample with known thickness 8) Setting the range of measurements 9) Indication of the range limits violation – with color, sound and vibro 10) Indication of residual thickness of the tested object in per cent 11) USB connection to PC for data transmission. Extra Features 1) Discreteness of thickness measuring 0,01 or 0,1 mm 2) Choice between mm and inches 3) Vibro indication 4) Signal level indication 5) Battery level indication. Operating Modes A-SCAN mode For measurings with displaying signals as A-Scan. This mode makes it possible to rule out inaccuracy of measurements caused by duplicated readings. There are four possible ways to conduct measuring: first overshoot of the strobe, maximum point at the strobe, between two signals and auto correlation function (ACF) in strobe. The “between two signals” mode allows to measure the thickness of metal through polymeric and varnish and paint coatings without skinning.NORM mode For quick thickness measuring with the possibility to set the range of automatical flaw alarm response and to detect the metal thickness derating. Sound and vibro indications when violating the limits of permissible results together with graphic presentation of the depth gauge scale provide comfort work. There is a possibility to measure thickness with indication of residual thickness of the controlled object in per cent of value preset by defining the upper limit indicating 100% and the lower limit indicating spoilage standart.MEMORY mode For quick thickness measuring with the possibility to save the result to the nonvolatile memory. While saving the readings can be organized in groups which make further viewing and analysis more convenient.Specification
Standart Delivery Kit
|